AlarmNet 7845C Guia de Configuração Página 29

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 48
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 28
Section 3: Programming the 7845GSM
3-15
PROMPTS ZONE
TRIG.
4204/
2-4204
ENTRY OPTIONS DESCRIPTION
47
Restore Zn5 Y/N
(Y)_
2-
4204
only
[Y], [N] Enables restore reporting for zone 5.
48
Delay Zn5 (secs)
(00)_
2-
4204
only
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 5.
49
Rpt Zn5 ONLY if
Armed (N)_
2-
4204
only
[Y], [N]
Reports alarms on zone 5 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 5.
50
Enable Zn6 Y/N
(N)_
4204
only
[Y], [N] Enables alarm reporting for zone 6.
If [N], skip to Prompt 56: "Enable Zn7."
51
Zn6 Trigger Type
(V+)_
4204
only
(EOLR)
(V+)
(V–)
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
52
Invert Zn6 Y/N
(N)_
4204
only
[Y], [N] Inverts the alarm and normal states of the zone
6 trigger; otherwise uses normal input signal.
53
Restore Zn6 Y/N
(Y)_
[Y], [N] Enables restore reporting for zone 6.
54
Delay Zn6 (secs)
(00)_
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 6.
55
Rpt Zn6 ONLY if
Armed (N)_
[Y], [N]
Reports alarms on zone 6 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 6.
56
Enable Zn7 Y/N
(N)_
4204
only
[Y], [N]
Enables alarm reporting for zone 7, if used.
If [N], skip to Prompt 64: "Review."
57
Zn7 Trigger Type
(V+)_
4204
only
(EOLR)
(V+)
(V–)
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
58
Invert Zn7 Y/N
(N)_
4204
only
[Y], [N] Inverts the alarm and normal states of the zone
7 trigger; otherwise uses normal input signal.
59
Restore Zn7 Y/N
(Y)_
[Y], [N]
Enables restore reporting for zone 7.
Zone Trigger mode: This question will only be
displayed if zone 7 is not used as the conditional
(arming) trigger zone.
60
Delay Zn7 (secs)
(00)_
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 7.
Zone Trigger mode: This question will only be
displayed if zone 7 is not used as the conditional
(arming) trigger zone.
61
Rpt Zn7 ONLY if
Armed (N)_
[Y], [N]
Reports alarms on zone 7 ONLY if the
conditional zone (zone 4 in 4204 mode; zone 8 in
2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 7.
2-4204 mode: If any zone is programmed to
"Report Only if Armed," or if tamper is enabled,
skip to "Review."
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
Vista de página 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 47 48

Comentários a estes Manuais

Sem comentários